Woodward 8446-1019 D RP3000 controller RP-3200-P2 operation screen

8446-1014 / 8446-1018 / 8446-1019 / 8446-1042

Category: SKU: 8446-1019 Tag:
Whatsapp:+86 13313705507
WeChat:+86 13313705507
E-mail:geabbdcs@gmail.com
Contacts:KEN HE

Description

To change a parameter of the easYgen-3000 Series, the corresponding code level of the CAN communication has to be activated. Insert the password for remote configuration. It does not matter whether the RP-3000 is connected via CAN1 or CAN2 of the easYgen-3000 Series. The code level of the corresponding interface will be activated automatically. The code level will be shown in the lock of the display of the RP-3000.

The indicator lights and internal equipment of SRPLC are beneficial for troubleshooting the entire PLC control system. The programmer is the main diagnostic tool that can be easily plugged into the PLC. On the programmer, you can observe the status of the entire control system. As a habit, you should bring a programmer when searching for faults in a control system with PLC as its core.


Basic fault finding sequence
Raise the following questions and deny each one based on the reasonable actions found. Replace various modules in SR step by step until all faults are resolved. All major corrective actions can be completed by replacing the module. Except for a screwdriver and a multimeter, there is no need for special tools, oscilloscopes, advanced precision voltmeters, or special testing programs.

1. Is the PWR (power supply) light on? If it does not light up, check the power supply voltage at the voltage input terminal (98-162VAC or 195-252VAC) of the frame using AC power supply; For frames that require DC voltage, measure the DC voltage between the+24VDC and 0VDC terminals. If it is not a suitable AC or DC power source, the problem occurs outside of the SRPLC. If the AC or DC power supply voltage is normal, but the PWR light is not on, check the fuse, and if necessary, replace the CPU frame.

2. Is the PWR (power supply) light on? If it is on, check the displayed error code, compare it with the code definition in the error code table, and make corresponding corrections.

3. Is the RUN light on? If it does not light up, check if the programmer is in the PRG or LOAD position, or if there is a program error. If the RUN light is not on and the programmer is not plugged in, or if the programmer is in RUN mode and no error code is displayed, the CPU module needs to be replaced.

4. Is the BATT light on? If it is on, the lithium battery needs to be replaced. Due to the fact that the BATT light is only an alarm signal, even if the battery voltage is too low, the program may not have changed yet. After replacing the battery, check the program or have the PLC test run. If the program has errors, after completing system programming initialization, reload the program recorded on the tape into the PLC.

5. In a multi frame system, if the CPU is working, the RUN relay can be used to check the operation of several other power supplies. If the RUN relay is not closed (high resistance state), follow the first step mentioned above to check the AC or DC power supply. If the AC or DC power supply is normal and the relay is disconnected, the frame needs to be replaced.

 

DSCA121
DSQC209
DSQC104
DSQC236A
DSQC259
ABB DSQC102
YYT102A
YTEA250-8
DSTC120
PCBOARD
DSQC104B
DSPC157
DSMB127
R/MEPROM
93-33-03
SERIALME
BACKPLANE
DRIVEUNI
DSSR-115
DSPC-153
DSMB-127
DSQC202