8521-HC-MT hybrid controller MTL

8521-HC-MT hybrid controller MTL

 

The 8507-BI-DP Bus Interface Module (BIM) provides the communications link between the PAC8000 series I/O modules and a PROFIBUS-DP host. High-speed acquisition of data from the modules and LAN operation speeds of up to 12 Mbaud allow the host to respond rapidly to changes in process conditions. The BIM gathers data from the I/O modules and makes it available to the host upon request. It is a slave to the PROFIBUS master. As well as cyclic data exchange, which is required for reading input and writing output data, the BIM supports PROFIBUS Extended Diagnostics for status information.

The BIM(s) must be used with an 8701-CA-BI Redundant BIM Carrier, described on page 4. Redundant BIMs can be used for critical applications. Each BIM in the redundant pair operates in parallel, continually checking status to enable the backup BIM to monitor the health of the primary BIM.

Features
 support for up to 24 I/O modules
 redundant operation
 extended diagnostics for module and channel status
 PROFIBUS network speeds of up to 12 Mbaud
 non-volatile memory for configuration
 configurable via PROFIBUS host
 HART Pass-through support to monitor/configure HART devices
 Configuration/Reset of IP address.

The 8507-BI-DP supports parameterization from the PROFIBUS master. The configuration is created in a PROFIBUS configurator using details provided in a GSD file. This method is fast and enables a configuration to be built based upon “logical” modules which represent the physical modules. Modules are added one at a time to the configuration.

The configuration is passed from the PROFIBUS master to the BIM at the start of communication. If the system is stopped and re-started, or if the node goes through a cold start cycle, the configuration file is retransmitted to the BIM.

 

8101-HI-TX 8-channel Analog Input Module, 4–20mA
8102-HO-IP 8-channel Analog Output Module, 4–20mA
8103-AI-TX 8-channel Analog Input Module, 4–20 Ma
8104-AO-IP 8-channel Analog Output Module, 4–20 mA
8105-TI-TC 4-channel THC/mV input
8106-TI-RT 4-channel RTD input
8109-DI-DC 8-channel Discrete Input Module, 24 V dc, isolated, sinking
8110-DI-DC 8-channel Discrete Input Module, 24 V dc, non-isolated, module powered
8111-DI-AC 8-channel Discrete Input Module, 115 V ac, isolated, sinking
8112-DI-AC 8-channel Discrete Input Module, 115 V ac, non-isolated, module powered
8113-DI-AC 8-channel Discrete Input Module, 230 V ac, isolated, sinking
8114-DI-AC 8-channel Discrete Input Module, 230 V ac, non-isolated, module powered
8115-DO-DC 8-channel Discrete Output Module, 2–60 V dc, non-isolated, module powered
8116-DO-AC 8-channel Discrete Output Module, 20–265 V ac, non-isolated, module powered
8117-DO-DC 8-channel Discrete Output Module, 2–60 V dc, isolated, unpowered
8118-DO-AC 8-channel Discrete Output Module, 20–265 V ac, isolated, unpowered
8119-VI-05 8-channel Analog Input Module, 1–5 V
8121-DI-DC 16-channel Discrete Input Module, 24 V dc, non-isolated, module powered
8122-DI-DC 16-channel Discrete Input Module, 24 V dc, isolated, sinking
8123-PI-QU 2-channel Pulse Quadrature Input
8125-DI-DC 32-Channel Discrete Input, Switch/Proximity Detector Inputs, Module Powered
8129-IO-DC 8-channel supervised DI
8132-AI-UN 8-channel, 4-20mA, Thermocouple, RTD and Voltage isolated, universal input
8140-DI-AC 16-channel Discrete Input Module, 115 V ac, block-isolated, sinking
8142-DO-DC 16-channel Discrete Output Module, 12-42 V dc, non-isolated, module powered