ABB AI830A Analog module industrial system controller

Numer modelu: AI830A
Manufacturer: ABB
Quantity:ten
Serial ports: 2
Network ports: 4
Port isolation: 280 VDC
Weight : 3 Kg
Shipping Weight : 4 Kg

Category:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

Manufacturer ABB
Brand ABB
Series module
Part Number AI830A
Product Type module
Quality 100% New Original
Stock In stock
Delivery time 1-3 days after Payment
After-sales Service Have
Warranty 1 year
Shipping term DHL / FEDEX/ EMS /UPS/TNT/EMS

 

Packaging details: if you need an urgent delivery order, please feel free to contact us, and we will do our best to meet your needs.

Price problem: if you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.

 

Parameters Range Factory setting
External PT Used** Disable
Demand integration time (I, U,F,P) 2s,5s,5m,8m,10m,15m,20m,30m,60m 10 mins
Event curves record point*** 30-70 % 30 %
DI/DOs
DI0 Main switch status
DI1 Main switch fault
DO Common warning
Maintenance
Running time alarm function Enable/Disable Disable
Insertion cycle alarm function Enable/Disable Disable
*Feedback is part of the monitoring function of main switch device status on/off. There are
two options available, i.e. via current measurement or main switch feedback (via DI0).
** If external PT is used, the PT primary range is 600-50,000VAC while secondary range is
100-690VAC.
*** Event curves record point is to define the pre-trigger point and the pre-recovery point. For
example, on a 240-samples event curve with 30% setting means 36 samples are recorded before the event is triggered while 84 samples are recorded after the event is detected. Another
36 samples are recorded before the event is recovered and 84 samples after recovery. More
details refer to event curve section.
5.3 User definable reading data
FC610 contains a user definable area in the memory map. This area allows re-mapping of the
addresses of any actual values or parameters registers. This makes it possible to reorganize
the reading data according to the project requirements and minimize the reading effort by
organize the required data in the registers next to each other.
Parameters have also been pre-loaded in user definable area which is in line with LVS digital
data integration requirements. For the details of parameters preloaded in FC610, please refer
to “1TNC928247 FC610 Modbus Protocol Implementation”.
Changing of the default mapping requires MConfig-G configuration tool locally if not updating through fieldbus.