BENTLY 130539-30 monitor provides mechanical protection

¥7,500.00

Manufacturer: Bently Nevada
Part number: 130539-30
Product catalog: 130539-30

Warranty maintenance: one year
Email: geabbdcs@gmail.com

Categories: , SKU: 130539-30 Tag:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

BENTLY 130539-30 monitor provides mechanical protection

 

130539-30 Adjust Button
Adjust the Zero Position voltage. When this 130539-30 button is clicked a utility starts that helps you set the direct zero position voltage. Since this utility provides active feedback from the 3500 rack, a connection with the rack is required. Refer to Section 5.2 (Adjusting the Scale Factor and the Zero Position).

130539-30 Transducer
The following transducer types are available for the Differential Expansion

130539-30 Channel:
25mm Extended Range Proximitor
35mm Extended Range Proximitor
50mm Extended Range Proximitor
Nonstandard

130539-30 Customize button
Used to adjust the Scale Factor of transducers. If Non-standard is selected as the transducer type, the OK Limits can also be adjusted. The Non-standard
transducer’s scale factor must be between 8.5 and 23 mV/mil. Also, there must be at least 2 volts between the Upper and Lower OK Limits.

 

BENTLY 130539-30 monitor provides mechanical protection

 

130539-30 Alarm Mode
Latching
Once an alarm is active, it will remain active even after the proportional value drops below the configured setpoint level. The channel will remain in alarm
until it is reset using one of the following methods:
– the reset switch on the front of the Rack Interface Module
– the contact on the Rack Interface I/O Module
– the Reset button in the Operator Display Software
– the reset command through the Communication Gateway Module
– the reset command through the Display Interface Module
– the reset command in the Rack Configuration Software

Nonlatching
When an alarm is active, it will go inactive as soon as the proportional value drops below the configured setpoint level. Alert should be the first level alarm that occurs when the transducer signal level exceeds the selected value. Danger should be the second level alarm that occurs when the transducer signal level exceeds the selected value. The Alert and Danger values are set on the Setpoint screen.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The Bently 3500 online vibration monitoring system from the United States is used for mechanical protection applications, for vibration monitoring of large and medium-sized rotating machinery such as steam turbines, compressors, fans, water pumps, coal mills, gearboxes, motors, etc. It is widely used in steel, power, metallurgy, petrochemical petroleum, natural gas, petrochemical, chemical and other related industrial fields. The highly modular design of the system includes:
Bently3500/05 Instrument Frame
Bently3500/15 power supply
Bently 3500/20 Framework Interface Module
Option Description
A: Power type (upper slot)
01 Low voltage AC (85 to 132 Vac rms)
0 2 High Voltage AC (175 to 264 Vac rms)
0 3 high-voltage direct current (88 to 140 Vdc)
0 4 low-voltage DC (20 to 30Vdc)
05 Universal Power Supply
B: Power type (lower slot)
0 0 No power supply (only used when a single power supply is required)
05 Universal Power Supply

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Related models:

3500/42M 140734-02
3500/42M 146449-02
3500/42M 176449-02
3500/42M-01-00
3500/42M-07-00
3500/44-01-00
3500/45
3500/45-01-00
3500/46M
3500/50
3500/50 133442-01
3500/50-01-00
3500/50-01-00-01
3500/50M
3500/53
3500/53 133388-01
3500/53-02-00
3500/53-03-00
3500/53M
3500/60
3500/60 163179-01
3500/61
3500/61-05-02
3500/62-04-00
3500/62-04-02
3500/64 140482-02
3500/65-01-00
3500/70M
3500/72M
3500/91
3500/92
3500/92 136180-01
3500/92-01-02-00
3500/92-02-01-00