XV-102-B6-35TQR-10-PLC EATON 5.7″ TOUCH PANEL

The XV-102-B6-35TQR-10-PLC is equipped with RS485 and Ethernet communication interfaces for data interaction with upper computers, touch screens, or other PLCs.

Category: Tag:
Whatsapp:+86 13313705507
WeChat:+86 13313705507
E-mail:geabbdcs@gmail.com
E-mail:info@geabb.com
Contacts:KEN HE

Description

XV-102-B6-35TQR-10-PLC Wiring Methods
1. Power Supply Wiring
The XV-102-B6-35TQR-10-PLC adopts a dual-power design, including main power supply and auxiliary power supply. For the main power supply, connect the AC 220V power source to the L and N terminals on the PLC power module (terminal numbers: L1, N1). Ensure the voltage fluctuation range is within ±10% to avoid abnormal operation caused by voltage instability. For the auxiliary power supply, which is used to power external sensors and input/output components, connect the DC 24V power supply to the +24V and 0V terminals (terminal numbers: DC+, DC-). It should be noted that the positive and negative poles must not be reversed during wiring; otherwise, the internal circuit of the PLC may be damaged.
In a large-scale automotive parts automated production line, the XVS-440-57MPI-1-1Z is employed as the core control component for the conveyor system. The production line requires precise synchronization of multiple conveyor sections to ensure the smooth transfer of auto parts between different processing stations, such as stamping, assembly and inspection. The XVS-440-57MPI-1-1Z, with its excellent MPI communication interface, realizes real-time data interaction with the upper PLC system. It accurately receives speed and position control commands from the PLC, and adjusts the operation parameters of the conveyor motor in real time to achieve synchronous operation of multiple conveyor belts.


2. Input Terminal Wiring
The XV-102-B6-35TQR-10-PLC is equipped with multiple digital input terminals (labeled as I0.0, I0.1, …, I3.7) and analog input terminals (labeled as AI0, AI1). For digital input wiring (e.g., connecting photoelectric sensors, limit switches), adopt the sinking or sourcing input mode according to the sensor type. In the sinking mode, connect the sensor’s signal output terminal to the digital input terminal, and the sensor’s common terminal to the +24V terminal of the auxiliary power supply. In the sourcing mode, connect the sensor’s signal output terminal to the digital input terminal, and the sensor’s common terminal to the 0V terminal. For analog input wiring (e.g., connecting pressure transmitters, temperature sensors), use shielded twisted-pair cables to reduce interference. Connect the signal positive pole of the sensor to the AI+ terminal, the signal negative pole to the AI- terminal, and the shield layer to the ground terminal of the PLC.
3. Output Terminal Wiring
The PLC’s output terminals are divided into relay output (labeled as Q0.0, Q0.1, …, Q3.7) and transistor output (labeled as T0.0, T0.1, …, T1.7). For relay output wiring (suitable for driving AC/DC loads such as contactors, solenoid valves), connect one end of the load to the output terminal and the other end to the power supply (AC 220V or DC 24V). The common terminal of the relay output (labeled as COM1, COM2) should be connected to the corresponding power supply terminal. For transistor output wiring (suitable for high-frequency switching loads such as stepping motors), adopt the sinking output mode: connect the load’s positive pole to the +24V terminal, and the load’s negative pole to the transistor output terminal; the common terminal (COM) is connected to the 0V terminal. It is recommended to install a freewheeling diode (for DC loads) or a varistor (for AC loads) in parallel at both ends of the load to protect the PLC output circuit.


4. Communication Interface Wiring
The XV-102-B6-35TQR-10-PLC is equipped with RS485 and Ethernet communication interfaces for data interaction with upper computers, touch screens, or other PLCs. For RS485 communication wiring, use shielded twisted-pair cables. Connect the A terminal of the PLC’s RS485 interface to the A terminal of the external device, and the B terminal to the B terminal of the external device; the shield layer is grounded at one end to avoid signal interference. For Ethernet communication wiring, use Cat5e or above unshielded twisted-pair cables. Insert one end of the cable into the PLC’s Ethernet port (RJ45 interface) and the other end into the network port of the external device (such as a router, upper computer). Ensure the network cable is properly crimped to ensure stable data transmission.
5. Wiring Precautions
Before wiring, cut off all power supplies to prevent electric shock or circuit damage. Ensure the wire cross-sectional area matches the current capacity (recommended 1.5mm² for power lines, 0.75mm² for signal lines). All wiring terminals should be tightened to avoid poor contact caused by loose connections. Keep power lines and signal lines separate (at least 10cm apart) to prevent electromagnetic interference. After wiring, check the correctness of the wiring again (especially the positive and negative poles of the power supply and the connection of input/output signals) before powering on the PLC. For outdoor or harsh environment applications, take protective measures such as waterproofing, dustproofing, and anti-corrosion for the wiring.
XV-102-B6-35TQR-10-PLC EATON PDF
XV-102-B6-35TQR-10-PLC

♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦

Shipping:
1. Your item will be shipped to all countries via EMS, unless one country cannot be shipped via EMS. We will choose DHL, UPS, or FedEx. Please leave us your phone number.
2. We will ship the product to you on the same day or within 1-2 working days after receiving your payment. The shipping time depends on the country/region where you reside, the customs and habits of your country/region, and especially during peak hours.
3. Assuming (assuming) that the item requires payment of tariffs from your country, the buyer is obligated. We are not responsible for any taxes or customs fees in your country/region.

Return Policy:
1. Please contact us before returning the item.
2. The buyer should inform the seller of all returned items within 7 days after receiving the package. We reserve the right to reject any request to inform the seller for more than 7 days.
3. Returned products must have all original packaging and be in good condition.

Response policy:
If you are satisfied with the purchase, please leave us an active response.
2. If you have any questions about the outcome of the transaction or product, please contact us first and we will do our best to satisfy you!
3. Please do not reply with negative feedback before contacting us!

Related models:

DS200LDCCH1A
DS200SDCCG4AFD
DS200SIOBH1ABA
DS200STBAG1A
DS200TCCAG1B
DS200TCEAG1B
DS200TCEAG1BTF
DS200TCQAG1B
DS200VPBLG2A
H201CI-1
H201TI
H201TI 220VAC
H20Ti
HYDRAN M2
IC693ALG392C