Description
- Response Time: <1ms electrical signal transmission to breakers via fast IGBT contacts
- Detector Capacity: 10 native optical detector inputs, expandable to 30 with 2 extension units
- Power Supply: 100–250V DC or 100–240V AC (50/60Hz)
- HMI Functionality: External door-mounted human-machine interface for real-time status monitoring
- Accessories: Compatible with current sensing units, optical cables, and cable straps for full switchgear integration
-
- 8 TVOC-2-240-C units installed across 4 switchgear bays, each connected to 8 optical detectors (custom-length for cabinet dimensions)
- Integrated with plant’s existing circuit breakers to enable zone-selective tripping
- HMI panels mounted on cabinet doors for local fault diagnostics
- Arc fault detection time reduced from 50ms (legacy system) to <1ms
- Zero unplanned outages in 18 months of operation
- Compliance with IEC 62271-200 arc flash protection standards
- TVOC-2-240-C units fitted with intrinsically safe optical detectors
- Current sensing units added to distinguish arc faults from normal load currents
- Interfaced with the refinery’s DCS via Modbus RTU protocol for remote monitoring
- Prevented 2 potential arc-induced fires by isolating faults within 0.8ms
- Reduced maintenance downtime by 35% through HMI-enabled predictive diagnostics
- Met NFPA 70E requirements for electrical safety in hazardous locations
- 1 TVOC-2-240-C unit per transformer, paired with 6 fiber-optic detectors (installed in tap-changer and busbar regions)
- Configured for sequential tripping: first isolating the tap-changer, then the main transformer breaker
- Linked to the plant’s SCADA system for fault event logging
- Successfully mitigated 3 minor arc events in 6 months, with no transformer damage
- Fault location identification time reduced from 4 hours to 5 minutes via HMI event logs
- Extended transformer service life by 2+ years through proactive fault prevention
- Personnel Safety: Eliminates arc flash exposure by extinguishing arcs before energy levels exceed 10kA
- Equipment Protection: Reduces breaker and switchgear replacement costs by 60–75%
- Flexibility: Adaptable to low/medium voltage systems (240V–33kV) and custom switchgear designs
- Reliability: 99.98% operational availability in harsh industrial environments (temperature range: -20°C to +70°C)

TVOC-2-240 1SFA664001R1001 TVOC-2-240-C PDF
TVOC-2-240 1SFA664001R1001 TVOC-2-240-C
♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦
Shipping:
1. Your item will be shipped to all countries via EMS, unless one country cannot be shipped via EMS. We will choose DHL, UPS, or FedEx. Please leave us your phone number.
2. We will ship the product to you on the same day or within 1-2 working days after receiving your payment. The shipping time depends on the country/region where you reside, the customs and habits of your country/region, and especially during peak hours.
3. Assuming (assuming) that the item requires payment of tariffs from your country, the buyer is obligated. We are not responsible for any taxes or customs fees in your country/region.
Return Policy:
1. Please contact us before returning the item.
2. The buyer should inform the seller of all returned items within 7 days after receiving the package. We reserve the right to reject any request to inform the seller for more than 7 days.
3. Returned products must have all original packaging and be in good condition.
Response policy:
If you are satisfied with the purchase, please leave us an active response.
2. If you have any questions about the outcome of the transaction or product, please contact us first and we will do our best to satisfy you!
3. Please do not reply with negative feedback before contacting us!
More models available: