SSA-G1018-0652 is a specialized industrial component (typically categorized as a signal conditioning module, sensor interface unit, or industrial communication adapter, based on common naming conventions for industrial automation components—often associated with manufacturers focusing on process control, such as Siemens, Yokogawa, or Rockwell Automation).
SSA-G1018-0652 is a specialized industrial component (typically categorized as a signal conditioning module, sensor interface unit, or industrial communication adapter, based on common naming conventions for industrial automation components—often associated with manufacturers focusing on process control, such as Siemens, Yokogawa, or Rockwell Automation).
1. Part Number Coding Interpretation
Industrial component part numbers usually use segmented codes to indicate core attributes such as product series, function, and key parameters. The coding of SSA-G1018-0652 is generally interpreted as follows (specifics may vary slightly by manufacturer; confirmation with the original supplier is recommended for exact details):
Code Segment
Typical Meaning
SSA
Product Series Identifier: Usually represents a specific product line, such as “Signal Conditioning Adapter” or “Sensor Signal Amplifier,” indicating the component’s core function is related to signal processing or sensor interface.
G
Product Category / Application Type: Often denotes the component’s application scenario or functional category, e.g., “G” for “General-Purpose” (suitable for broad industrial environments) or “Gateway” (implying protocol conversion capabilities).
1018
Key Technical Parameters: Typically a composite code for core specs, such as: – Number of input/output channels (e.g., “10” = 10 signal input channels, “18” = 18 signal output channels); – Signal type (e.g., “10” for analog signals, “18” for digital signals); – Power supply range (e.g., “1018” corresponding to 10–18 VDC auxiliary power).
0652
Configuration / Version / Manufacturing Info: Usually indicates specific configurations, hardware versions, or production batch codes. For example: – “06” = 6 communication ports (e.g., RS-485, Ethernet); – “52” = firmware version 5.2 or a specific factory configuration code.
2. Typical Basic Specifications
Based on the part number’s implied function (signal conditioning/interface) and common industry standards for similar components, the basic specifications of SSA-G1018-0652 are typically as follows (note: exact values require confirmation with the manufacturer’s official documentation):
(1) Core Function
Primary Function: Signal conditioning (amplification, filtering, isolation) for sensor signals (e.g., thermocouple, RTD, 4–20 mA analog signals) or industrial protocol conversion (e.g., converting Modbus RTU to Ethernet/IP).
Signal Processing: Supports noise reduction and interference suppression for analog/digital signals, ensuring stable data transmission in harsh industrial environments.
(2) Input/Output (I/O) Specifications
Parameter
Typical Specifications
Input Channels
8–16 channels (analog/digital, depending on “1018” coding; e.g., 10 analog input channels + 8 digital input channels).
Input Signal Types
Analog: 4–20 mA DC, 0–10 V DC, thermocouple (K/J/T type), RTD (Pt100/Pt1000); Digital: NPN/PNP discrete signals (24 VDC).
Output Channels
4–12 channels (e.g., 6 analog output channels + 6 digital output channels, per “0652” coding).
Output Signal Types
Analog: 4–20 mA DC, 0–5 V DC; Digital: Relay contacts (NO/NC) or open-collector outputs.
Signal Isolation
Input/output/ power supply triple isolation, isolation voltage ≥ 2500 V AC (50 Hz, 1 minute) to prevent ground loops and electromagnetic interference (EMI).
(3) Communication Capabilities
Communication Ports: 2–6 ports (per “0652” coding), including: – Serial ports: RS-232/RS-485 (supports Modbus RTU/ASCII protocol); – Ethernet port: 10/100 Mbps RJ45 (supports Modbus TCP, Ethernet/IP, or PROFINET, depending on configuration).
Data Transmission Rate: Serial: Up to 115200 bps; Ethernet: Up to 100 Mbps.
(4) Power Supply
Auxiliary Power Input: 10–30 VDC (wide-range design, compatible with most industrial power systems) or 85–265 V AC (for AC-powered versions).
Power Consumption: Typical ≤ 10 W (no-load); maximum ≤ 15 W (full-load operation).
(5) Environmental Adaptability
Operating Temperature Range: -20°C to +60°C (standard industrial grade); -40°C to +70°C (wide-temperature version, optional).
Relative Humidity: 5%–95% RH (non-condensing, no dew formation).
Protection Level: IP20 (panel-mounted) or IP65 (field-mounted, optional), dust-proof and splash-proof.
EMI/EMC Compliance: Meets IEC 61000-6-2 (industrial immunity) and IEC 61000-6-4 (industrial emissions) standards, resistant to electromagnetic interference from nearby motors or power lines.
(6) Physical & Mechanical Specifications
Mounting Type: DIN rail mounting (compatible with TS35 standard rails) or panel mounting.
Dimensions (W×H×D): Approximately 35 mm × 100 mm × 120 mm (DIN rail-mounted, typical for 1–2 slot industrial modules).
Weight: Approximately 200–300 g (depending on hardware configuration).
3. Typical Application Scenarios
SSA-G1018-0652 is suitable for industrial automation scenarios requiring signal processing or protocol integration, such as:
Process Control Systems: Conditioning temperature, pressure, or flow sensor signals (e.g., in chemical plants, oil refineries) to ensure accurate data collection by PLCs/DCS.
Remote Monitoring: Enabling protocol conversion for field devices (e.g., Modbus RTU sensors) to connect to Ethernet-based SCADA systems, supporting remote data monitoring and control.
Shipping:
1. Your item will be shipped to all countries via EMS, unless one country cannot be shipped via EMS. We will choose DHL, UPS, or FedEx. Please leave us your phone number.
2. We will ship the product to you on the same day or within 1-2 working days after receiving your payment. The shipping time depends on the country/region where you reside, the customs and habits of your country/region, and especially during peak hours.
3. Assuming (assuming) that the item requires payment of tariffs from your country, the buyer is obligated. We are not responsible for any taxes or customs fees in your country/region.
Return Policy:
1. Please contact us before returning the item.
2. The buyer should inform the seller of all returned items within 7 days after receiving the package. We reserve the right to reject any request to inform the seller for more than 7 days.
3. Returned products must have all original packaging and be in good condition.
Response policy:
If you are satisfied with the purchase, please leave us an active response.
2. If you have any questions about the outcome of the transaction or product, please contact us first and we will do our best to satisfy you!
3. Please do not reply with negative feedback before contacting us!