Description
1. Intended Use
Critical Note: The motor’s rated voltage must be at least equal to the DC bus link voltage divided by 2 (UnMotor ≥ UDC/2) as produced by the servo amplifier.
2. Functional Safety
- When utilizing the safety function STO (Safe Torque Off), refer to the chapter “Use as Directed” on page 39.
- To achieve PL e or SIL CL3 safety levels, the safe switching of the pulse inhibitor must be periodically tested by analyzing the feedback signal from the safety control (see page 47).
- If using a safety expansion card (S1-2(S3) / S2-2(S4)), strictly follow the instructions provided in the card’s user documentation.
2.3 Prohibited Use
- Potentially explosive areas.
- Environments exposed to corrosive and/or electrically conductive substances (e.g., acids, alkaline solutions, oils, vapors, dusts).
- Direct connection to non-grounded supply networks or asymmetrically grounded supplies with a voltage >240V.
- Marine or offshore applications.
- Fails to meet the requirements of the EC Machinery Directive.
- Does not comply with the EMC Directive or Low Voltage Directive.
- Violates any applicable national directives.
- The S748/772 servo amplifier alone may not be used to control holding brakes in applications where functional safety relies on the brake.
- The servo amplifier contains electrostatically sensitive components. To prevent damage:
- Discharge static electricity from your body before handling the unit.
- Avoid contact with highly insulating materials (e.g., synthetic fabrics, plastic films).
- Place the servo amplifier on a conductive surface during handling.
3. Packaging
- Material: Recyclable cardboard with protective inserts.
- Dimensions: 390 x 600 x 400 mm.
- Labeling: Nameplate affixed to the exterior of the box.
3.3 Storage
3.3.1 General Storage Requirements
- Store only in the manufacturer’s original recyclable packaging.
- Maximum stacking height: 3 cartons.
3.3.2 Environmental Conditions
- Temperature: -25°C to +55°C; maximum temperature change rate: 20K/hour (class 1K4 per EN61800-2, EN 60721-3-1).
- Humidity: 5–95% relative humidity (non-condensing; class 1K3 per EN61800-2, EN 60721-3-1).
3.3.3 Storage Duration
- Less than 1 year: No additional restrictions.
- More than 1 year: Capacitors must be re-formed before commissioning:
- Disconnect all electrical connections.
- Apply single-phase 230V AC to terminals L1/L2 for approximately 30 minutes.
S72402-NANANA-NA-225 PDF
s701_e_0
♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦
Shipping:
1. Your item will be shipped to all countries via EMS, unless one country cannot be shipped via EMS. We will choose DHL, UPS, or FedEx. Please leave us your phone number.
2. We will ship the product to you on the same day or within 1-2 working days after receiving your payment. The shipping time depends on the country/region where you reside, the customs and habits of your country/region, and especially during peak hours.
3. Assuming (assuming) that the item requires payment of tariffs from your country, the buyer is obligated. We are not responsible for any taxes or customs fees in your country/region.
Return Policy:
1. Please contact us before returning the item.
2. The buyer should inform the seller of all returned items within 7 days after receiving the package. We reserve the right to reject any request to inform the seller for more than 7 days.
3. Returned products must have all original packaging and be in good condition.
Response policy:
If you are satisfied with the purchase, please leave us an active response.
2. If you have any questions about the outcome of the transaction or product, please contact us first and we will do our best to satisfy you!
3. Please do not reply with negative feedback before contacting us!