Description
1. RHUB200-5 603442 Kongsberg Technical Parameters
Manufacturer: Kongsberg Maritime
Model: RMP200-8
Part number: 603443
Product type: Remote Multipurpose I/O Module
I/O channels: 8
Communication: Dual RBUS interfaces
Nominal power supply: 24 V DC
Parameter Specification
Power supply range +18 to +32 V DC
Standby current 0.25 A typical
Analog input range ±10 V; 0–20 mA
Analog output range ±10 V; 0–20 mA
Analog resolution 16-bit
Digital input Configurable on supported channels
Digital output 24 V DC high-side driver, 0.1 A per channel
Maximum combined digital output current 0.3 A
Communication interface Dual RBUS, RS-485
Communication speed 2 Mbps
Maximum modules per RBUS 99
Galvanic isolation Up to 500 V DC, depending on interface and channel
Dimensions (W × H × D) 35 × 130 × 130 mm
Weight Approximately 0.35 kg
Mounting Dual DIN rail
Operating temperature −15°C to +70°C
Storage temperature −25°C to +70°C
Protection rating IP20
Standards IEC 60945, IACS E10
-
RMP200-8 603443
2. RHUB200-5 603442 Kongsberg Main Functions
Analog signal acquisition: Reads compatible voltage and current signals from field transmitters.
Digital signal processing: Monitors supported discrete signals from switches and other field devices.
Analog output control: Generates configurable voltage or current outputs for compatible control equipment.
Digital output control: Drives supported 24 V DC loads within the specified current limits.
Redundant communication: Provides dual RBUS communication and power interfaces.
Fault diagnostics: Includes status indication, watchdog supervision, and detection of supported wiring or signal faults.
Fail-safe operation: Supports configured output behavior when communication or module faults occur.
3.RHUB200-5 603442 Kongsberg Typical Applications
Shipboard machinery monitoring and control
Engine-room automation
Marine power management
Propulsion and auxiliary equipment control
Distributed I/O in Kongsberg marine automation systems
Compatible K-Pos and K-Chief installations, depending on system configuration
4.RHUB200-5 603442 Kongsberg Installation and Commissioning
1. Verify the module: Check part number 603443, hardware revision, and serial number.
2. Isolate the power: Follow the vessel’s approved lockout procedures before installation or wiring.
3. Install the module: Mount it on the specified dual DIN-rail and RBUS connector assembly.
4. Set the module address: Configure the address switches to a unique value from 1 to 99 on the applicable RBUS.
5. Connect field wiring: Wire each channel according to its configured signal type and the official terminal diagram.
6. Verify communication: Check the RBUS connection and front-panel status LED.
7. Test I/O: Validate analog readings, digital states, output behavior, and configured fail-safe responses.
8. Complete functional checks: Confirm correct operation through the host control system before returning equipment to service.
-
RMP200-8 603443
♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦
Shipping:
1. Your item will be shipped to all countries via EMS, unless one country cannot be shipped via EMS. We will choose DHL, UPS, or FedEx. Please leave us your phone number.
2. We will ship the product to you on the same day or within 1-2 working days after receiving your payment. The shipping time depends on the country/region where you reside, the customs and habits of your country/region, and especially during peak hours.
3. Assuming (assuming) that the item requires payment of tariffs from your country, the buyer is obligated. We are not responsible for any taxes or customs fees in your country/region.
Return Policy:
1. Please contact us before returning the item.
2. The buyer should inform the seller of all returned items within 7 days after receiving the package. We reserve the right to reject any request to inform the seller for more than 7 days.
3. Returned products must have all original packaging and be in good condition.
Response policy:
If you are satisfied with the purchase, please leave us an active response.
2. If you have any questions about the outcome of the transaction or product, please contact us first and we will do our best to satisfy you!
3. Please do not reply with negative feedback before contacting us!