PQM-T20-C-A GE Power Quality Meter BRAND NEW

GE PQM-T20-C-A is a high-precision three-phase power quality meter developed by GE Multilin, used for comprehensive power monitoring and energy measurement of low and medium voltage power distribution systems. It adopts True RMS sampling technology, which can continuously measure voltage, current, active/reactive power, power factor, frequency, energy consumption and harmonic data up to the 63rd harmonic. This unit supports waveform capture, voltage sag/swell disturbance recording and event logging.

Category: Tag:
Whatsapp:+86 13313705507
WeChat:+86 13313705507
E-mail:geabbdcs@gmail.com
E-mail:info@geabb.com
Contacts:KEN HE

Description

GE PQM-T20-C-A Power Quality Meter Product Introduction
Brand: GE (General Electric / Multilin);
Model: PQM-T20-C-A;
Product Name: Power Quality Meter;
Dimensions: 144mm × 144mm × 120mm;
Weight: Approximately 1.15kg;
Place of Origin: USA;
HS Code: 90283010;
Operating Temperature: -20°C ~ +60°C;
Storage Temperature: -40°C ~ +85°C;
Relative Humidity: 5% to 95% RH, non-condensing;
Rated Control Power: 70-265V AC / 100-300V DC;
Current Input: 1A or 5A CT secondary input;
Voltage Input: 20V ~ 600V AC phase-to-phase;
Input: Three-phase voltage and current signal input, 4 digital status switch inputs;
Output: 3 channels configurable 4-20mA analog outputs (T20 option), 3 Form C relay alarm outputs, pulse energy output;
Communication Interface: RS485, Modbus RTU;
Sampling Rate: 64 samples per cycle;
Measurement Accuracy: ±0.2% for voltage and current; ±0.4% for power and energy;
Harmonic Measurement: Up to 63rd harmonic, THD calculation;
Mounting Type: Panel cutout mounting;
Protection Class: IP50 front panel;
Features: True RMS measurement, harmonic analysis, voltage disturbance recording, built-in event recorder, programmable set points, high accuracy energy metering, multi-parameter real-time display, strong EMC anti-interference, flexible analog and relay output configuration, non-volatile data storage;
Functions: Real-time monitoring of three-phase electrical parameters, energy consumption statistics, power quality harmonic detection, capture voltage sags, swells and transients, over/under voltage & overcurrent alarm, breaker status monitoring, transmit measurement data to upper SCADA system, generate power consumption reports and fault event logs.

PQM-T20-C-A

PQM-T20-C-A

GE PQM-T20-C-A FAQ
Q1: What is GE PQM-T20-C-A used for?
A1: GE PQM-T20-C-A is a three-phase power quality meter. It monitors voltage, current, power, energy and harmonics for power distribution systems, records power disturbances and sends measurement data to SCADA or energy management platforms.
Q2: What is the power supply range for PQM-T20-C-A?
A2: The control power supports 70–265V AC or 100–300V DC wide range power supply.
Q3: What are the input specifications of this power quality meter?
A3: Voltage input range is 20V~600V AC phase to phase; current input supports 1A or 5A CT secondary signals, with 4 digital status inputs for switch/breaker feedback.
Q4: What output signals does PQM-T20-C-A provide?
A4: It has 3 configurable 4-20mA analog outputs, 3 Form C relay alarm contacts and pulse output for energy metering.
Q5: What communication protocol does GE PQM-T20-C-A use?
A5: It uses RS485 physical interface and supports Modbus RTU protocol for data communication with PLC, SCADA and HMI.

PQM-T20-C-A

PQM-T20-C-A

♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦

Shipping:
1. Your item will be shipped to all countries via EMS, unless one country cannot be shipped via EMS. We will choose DHL, UPS, or FedEx. Please leave us your phone number.
2. We will ship the product to you on the same day or within 1-2 working days after receiving your payment. The shipping time depends on the country/region where you reside, the customs and habits of your country/region, and especially during peak hours.
3. Assuming (assuming) that the item requires payment of tariffs from your country, the buyer is obligated. We are not responsible for any taxes or customs fees in your country/region.

Return Policy:
1. Please contact us before returning the item.
2. The buyer should inform the seller of all returned items within 7 days after receiving the package. We reserve the right to reject any request to inform the seller for more than 7 days.
3. Returned products must have all original packaging and be in good condition.

Response policy:
If you are satisfied with the purchase, please leave us an active response.
2. If you have any questions about the outcome of the transaction or product, please contact us first and we will do our best to satisfy you!
3. Please do not reply with negative feedback before contacting us!

Related models:
350-E-P5-G5-H-S-S-N-M-1E-N-N
 IS215WETAH1C
G60G01HCHF8FH6PM8HP6PU6PWXX
DS200SDCCG1A
IS200VTURH1B
IC695ALG626
IS200BAPAH1A
IS200STCIH4A
IS220PDOAH1B
IS200TDBSH6A
SH070/60010/0/0/00/00/00/10/00

SH140/30270/0/1/00/00/00/00/00
SM100-50-030-P1-45-S1-B0
SH100/30060/3/1/00/20/00/20/00
SM-100-40-050-P1-45-S1-B0
SR-058/60/005/P0/21/M1/B0/T
 SH140/30330/0/0/02/00/00/11/00 
SH31402P12F2000
SM140-30-290-P0-45-S1-B1
S403M-CA
BSM80C-275AFX
RED615E_1G HBDAACADAKC1ANN11G
PM891K01 3BSE053241RI
05701-A-0351
05701-A-0551
05701-A-0327
151X1235BC01SA41