PFCL201CE-50KN 3BSE027062R50 ABB Pressductor PillowBlock Load Cells

his LED blinks Orange and then Blue

during the boot process. When the operating

system starts running, the WiFi driver changes

the LED color depending on the signal strength

of its connection to its associated access point.

Colors for signal strength: Orange=Fair to Good,

Blue=Excellent, No Light=No connection or not

enabled, and Red=Poor signal strength.

Category: Tag:
Whatsapp:+86 13313705507
WeChat:+86 13313705507
E-mail:geabbdcs@gmail.com
Contacts:KEN HE

Description

PFCL201CE-50KN 3BSE027062R50 ABB Pressductor PillowBlock Load Cells

The information in this document is subject to change without notice and should not be construed as a commitment by ABB . ABB AB assumes no responsibility for any errors that may appear in this document.In no event shall ABB AB be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, nor shall ABB AB be liable for incidental or consequential damages arising from use of any

software or hardware described in this document.This document and parts thereof must not be reproduced or copied without ABB AB’s written permission, and the contents thereof must not be imparted to a third party nor be used for any unauthorized purpose.The software described in this document is furnished under a license and may be used, copied, or disclosed only in accordance with the terms of such license.

PFCL201CE-50KN 3BSE027062R50 ABB Pressductor PillowBlock Load Cells

PFCL201CE-50KN 3BSE027062R50 ABB Pressductor PillowBlock Load Cells

Load Cells PFCL 201
The load cells are installed under the roll bearings, where they measure forces at right angles to the mounting surface.The reactive force from the strip, which is proportional to the strip tension, is transferred to the load cells via the roll and the bearings.The load cells are connected to the control unit via a junction box. The control unit converts the load cell signals to DC voltages that are proportional to the reaction force. Depending on which control unit is chosen, it is possible to have the analog signals for the two individual load cells (A and B), the sum of the load cell signals (A+B), and/or the difference between the load cell signals(A-B).

Principle of Measurement
The load cell only measures force in the direction FR. The measurement force may be positive or negative. The load cell is normally installed under the roll bearings. When there is a strip in tension over the roll, the tension (T) gives rise to two force components, one in the direction of measurement of the load cell (FR) and one at right angles (FV).The measuring force depends on the relationship between the tension (T) and the wrap angle formed by the strip around the measuring roll.

PFCL201CE-50KN 3BSE027062R50 ABB Pressductor PillowBlock Load Cells

PFCL201CE-50KN 3BSE027062R50 ABB Pressductor PillowBlock Load Cells

The load cell is supplied with a 0.5 A, 330 Hz alternating current. The secondary signal is calibrated for the correct sensitivity with a voltage divider R1- R2, and temperature compensation is provided by thermistors T.All impedances on the secondary side are relatively low. The output impedance is typically 9-12 Ω ,which helps to suppress interference.

Horizontal Mounting
In the majority of cases horizontal mounting is the most obvious and simplest solution. Stand,
mounting surface and shims (if required) are simple and cheap to make.
When calculating the force, the equations below must be used:
FR = T × (sin α + sin β)
FRT = Tare
FRtot = FR + FRT = T × (sin α + sin β) + Tare
FV
= T × (cos β – cos α)
FVT = 0
FVtot = FV
+ FVT = T × (cos β – cos α) + 0 = T × (cos β – cos α)
where:
T = Strip tension
FR = Force component from strip tension in measurement direction, R
FRT = Force component from Tare in measurement direction, R
FRtot = Total force in measurement direction, R
FV
= Force component from strip tension in transverse direction, V
FVT = Force component from Tare in transverse direction, V
FVtot = Total force in transverse direction, V
Tare = Force due to tare weight
α = #eflectHon angle on one side of the roll relative the horizontal plane
β = #eflectHon angle on the other side of the roll relative the horizontal plane

PFCL201CE-50KN 3BSE027062R50 ABB Pressductor PillowBlock Load Cells pdf

PFCL201CE-50KN 3BSE027062R50

PFCL201CE-50KN 3BSE027062R50 ABB Pressductor PillowBlock Load Cells

♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦

Shipping:
1. Your item will be shipped to all countries via EMS, unless one country cannot be shipped via EMS. We will choose DHL, UPS, or FedEx. Please leave us your phone number.
2. We will ship the product to you on the same day or within 1-2 working days after receiving your payment. The shipping time depends on the country/region where you reside, the customs and habits of your country/region, and especially during peak hours.
3. Assuming (assuming) that the item requires payment of tariffs from your country, the buyer is obligated. We are not responsible for any taxes or customs fees in your country/region.

 

Return Policy:
1. Please contact us before returning the item.
2. The buyer should inform the seller of all returned items within 7 days after receiving the package. We reserve the right to reject any request to inform the seller for more than 7 days.
3. Returned products must have all original packaging and be in good condition.

 

Response policy:
If you are satisfied with the purchase, please leave us an active response.
2. If you have any questions about the outcome of the transaction or product, please contact us first and we will do our best to satisfy you!
3. Please do not reply with negative feedback before contacting us!

 

 

More models available:

DS200CTBAG1ADD

9905-263

5233-2089

IC8008SI228RD2

8237-1006

5233-2089

8446-1019

EASYGEN-3500-5/P2 8440-2145

9905-017

8200-314