Description
Basic Technical Specifications of MMS6312 Single-Channel Axial Displacement & Vibration Monitoring Module
(Emerson EPRO MMS6000 Series)
- Measurement Configuration
Channel Quantity: 1 single channel (configurable for axial displacement or radial vibration)
Measurement Type:
Axial displacement (shaft position)
Radial vibration (velocity/displacement)
Optional: Differential expansion (with compatible sensors)
- Input Specifications
Sensor Compatibility:
Eddy current proximity probes (e.g., EPRO PR64xx series, 3-wire)
Electric velocity sensors (e.g., EPRO PR926xx series, 2-wire)
Input Signal Range:
Eddy current probes: -20V to +20V DC (displacement measurement)
Velocity sensors: -5V to +15V DC (velocity measurement)
Sensor Supply:
For eddy current probes: 24V DC ±10%, max. 20mA per channel (integrated probe driver)
For velocity sensors: 0-8mA lift-off current (adjustable)
- Measurement Performance
Frequency Range:
Displacement measurement: 0.1Hz to 1000Hz
Velocity measurement: 5Hz to 1600Hz
Measurement Range:
Axial displacement: 0-2000μm (configurable via software, dependent on probe range)
Radial vibration (velocity): 0-50mm/s RMS (0-141.4mm/s peak)
Radial vibration (displacement): 0-1000μm peak-peak
Accuracy: ±1% of full scale (FS) at 25°C
Resolution: 0.01μm (displacement); 0.01mm/s (velocity)
- Output Signals
Analog Output: 1 x 4-20mA DC current output (isolated, load resistance: 0-500Ω)
Corresponding to measured value (configurable full-scale range)
Dynamic Signal Output: 1 x 0-20Vpp (peak-peak) AC signal, bandwidth 0.1Hz-10kHz
For spectrum analysis and fault diagnosis
Relay Output: 1 x changeover relay (NO/NC configurable)
Contact rating: 250V AC / 3A, 30V DC / 3A
Triggered by alarm/danger thresholds or module fault
- Alarm & Protection Functions
Threshold Settings: Configurable “Warning” and “Danger” thresholds (software-adjustable)
Alarm Features:
Alarm latching (manual/automatic reset configurable)
Limit multiplier (temporary threshold adjustment for critical speed transients)
Sensor fault detection (open/short circuit, signal loss)
Module self-diagnosis (power supply, internal circuit integrity)
Fault Indication: LED indicator (red/yellow/green) + relay output + software status feedback
- Power Supply
Input Voltage: 24V DC ±15% (redundant input optional)
Power Consumption: Max. 5W (typical 3W)
Reverse Polarity Protection: Yes (integrated diode protection)
- Environmental Conditions
Operating Temperature: -20°C to +70°C (-4°F to +158°F)
Storage Temperature: -40°C to +85°C (-40°F to +185°F)
Relative Humidity: 5% to 95% (non-condensing)
Vibration Resistance: 10g (10-2000Hz) per IEC 60068-2-6
Shock Resistance: 30g (11ms half-sine) per IEC 60068-2-27
Protection Rating: IP20 (front panel); IP65 (optional for harsh environments)
- Mechanical & Installation
Mounting: DIN rail mounting (EN 50022, 35mm)
Dimensions: 17.5mm (width) x 120mm (height) x 115mm (depth)
Weight: Approx. 150g (without wiring)
Hot-Swappable: Yes (supports on-line replacement without system shutdown)
- Communication Interface
Configuration Interface: RS232 (local) / RS485 (remote), Modbus RTU protocol
Data Output: Measured values, alarm status, fault codes, sensor health data
- Certifications & Compliance
Safety Certifications: CE, UL, CSA
EMC Compliance: EN 61000-6-2 (immunity), EN 61000-6-4 (emission)
Industrial Standards: Compliant with ISO 10816, API 670, DIN 45670
MMS6312 PDF
♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦
Shipping:
1. Your item will be shipped to all countries via EMS, unless one country cannot be shipped via EMS. We will choose DHL, UPS, or FedEx. Please leave us your phone number.
2. We will ship the product to you on the same day or within 1-2 working days after receiving your payment. The shipping time depends on the country/region where you reside, the customs and habits of your country/region, and especially during peak hours.
3. Assuming (assuming) that the item requires payment of tariffs from your country, the buyer is obligated. We are not responsible for any taxes or customs fees in your country/region.
Return Policy:
1. Please contact us before returning the item.
2. The buyer should inform the seller of all returned items within 7 days after receiving the package. We reserve the right to reject any request to inform the seller for more than 7 days.
3. Returned products must have all original packaging and be in good condition.
Response policy:
If you are satisfied with the purchase, please leave us an active response.
2. If you have any questions about the outcome of the transaction or product, please contact us first and we will do our best to satisfy you!
3. Please do not reply with negative feedback before contacting us!