DPM-MC2 EATON Communication module

The DPM-MC2 is ideally suited for industrial automation systems requiring PROFIBUS DP communication capabilities, including manufacturing control, process automation, and building management systems where reliable data exchange between MICRO PANEL MC2 HMI devices and field-level equipment is essential.

Category: Tag:
Whatsapp:+86 13313705507
WeChat:+86 13313705507
E-mail:geabbdcs@gmail.com
E-mail:info@geabb.com
Contacts:KEN HE

Description

Eaton DPM-MC2 Communication Module: Overview and Technical Specifications
Brand and Model Identification
Brand: Eaton Automation AGModel: DPM-MC2Product Type: PROFIBUS DP Master Communication Module for MICRO PANEL MC2 Series Devices
Product Overview
The DPM-MC2 is a specialized communication interface designed exclusively for integration with Eaton’s MICRO PANEL MC2 series devices, requiring a dedicated slot for installation. As a PROFIBUS DP master module compliant with the EN50170 standard, it enables seamless data exchange between MICRO PANEL MC2 units and other PROFIBUS-compatible industrial devices, significantly expanding the communication capabilities and application scope of the host system. Installation and removal must only be performed when the device is de-energized to ensure safety and prevent damage.

DPM-MC2

DPM-MC2

Technical Specifications
Physical and Interface Specifications
Communication Interface: Isolated PROFIBUS DP with 9-pole D-Sub female connector (compliant with EN50170 standard)
Connector Pin Assignment: Pin 3 (RxD/TxD-P), Pin 4 (CNTR-P), Pin 5 (DGND – Data Ground for termination), Pin 6 (VP – Voltage-Plus +5V for termination), Pin 8 (RxD/TxD-N), Case (Shield), Pins 1, 2, 7, 9 are not connected (nc)
Mechanical Compatibility: Designed for MICRO PANEL MC2 series devices only
Power Requirements
Termination Power: VP (Pin 6) provides +5V DC for PROFIBUS line termination; DGND (Pin 5) serves as the corresponding ground connection
Power Source: Derives operational power from the host MICRO PANEL MC2 device
Operational Parameters
Operating Temperature: 0°C to +50°C
Storage Temperature: -20°C to +60°C
Relative Humidity: 10% to 95% (non-condensing) for both operating and storage conditions
Vibration Resistance: Compliant with IEC68-2-6 standard
Shock Resistance: Compliant with IEC68-2-27 standard
Fall Test Compliance: Meets IEC68-2-32 requirements
Compliance and Safety
EMC Compliance: Conforms to EN 61000-6-2 and EN 61000-6-4 standards, as well as EN 61131-2 for PLC equipment
Safety Certification: Compliant with EN 60950 and UL 60950 standards
Product Standards: Adheres to EN 50178 (Electrical equipment for electrical installations) and EN 61131-2 (PLC specifications)
Functional Features
LED Status Indicators (Front Panel)
READY (Yellow): Lit when CIF (Communication Interface) is ready; flashing cyclically during bootstraploader operation; flashing irregularly indicates hardware/system error; dark signifies hardware fault
RUN (Green): Lit during active communication; flashing cyclically when communication is stopped; flashing irregularly indicates missing or faulty configuration; dark means no communication activity
ERROR (Red): Lit when PROFIBUS error is detected; dark indicates no error condition
STATUS (Yellow): Lit when sending data or token; dark when no token is present
Communication Capabilities
PROFIBUS Role: Functions as a full PROFIBUS DP master controller
Data Exchange: Facilitates real-time data transfer between MICRO PANEL MC2 and connected PROFIBUS DP slaves
Bus Termination: Supports proper bus termination at both ends of each segment (max 2 terminations per segment; at least one must be powered by a bus station)
Repeater Compatibility: CNTR-P signal (Pin 4) enables integration with PROFIBUS repeaters
Key Performance Characteristics
Isolation: Provides electrical isolation for PROFIBUS signals to prevent ground loops and ensure signal integrity
Diagnostics: Comprehensive LED status indicators for quick troubleshooting of communication and system issues
Reliability: Industrial-grade design for continuous operation in harsh environments
Compliance: Fully compliant with international PROFIBUS and safety standards for industrial applications

DPM-MC2

DPM-MC2

DPM-MC2 EATON pdf
DPM-MC2 EATON

♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦

Shipping:
1. Your item will be shipped to all countries via EMS, unless one country cannot be shipped via EMS. We will choose DHL, UPS, or FedEx. Please leave us your phone number.
2. We will ship the product to you on the same day or within 1-2 working days after receiving your payment. The shipping time depends on the country/region where you reside, the customs and habits of your country/region, and especially during peak hours.
3. Assuming (assuming) that the item requires payment of tariffs from your country, the buyer is obligated. We are not responsible for any taxes or customs fees in your country/region.

Return Policy:
1. Please contact us before returning the item.
2. The buyer should inform the seller of all returned items within 7 days after receiving the package. We reserve the right to reject any request to inform the seller for more than 7 days.
3. Returned products must have all original packaging and be in good condition.

Response policy:
If you are satisfied with the purchase, please leave us an active response.
2. If you have any questions about the outcome of the transaction or product, please contact us first and we will do our best to satisfy you!
3. Please do not reply with negative feedback before contacting us!

Related models:

DS200LDCCH1A
DS200SDCCG4AFD
DS200SIOBH1ABA
DS200STBAG1A
DS200TCCAG1B
DS200TCEAG1B
DS200TCEAG1BTF
DS200TCQAG1B
DS200VPBLG2A
H201CI-1
H201TI
H201TI 220VAC
H20Ti
HYDRAN M2
IC693ALG392C