Description

9907-173 Woodward Power Requirements & Shielded Wiring Guidelines

  1. 9907-173 Woodward Power Requirements

The Load Sharing Module is powered via potential transformer connections.

Jumpers are used to configure the module for the generator’s output voltage:

For 95–130 Vac generator output: Jumper terminals 15–16 and 17–18

For 190–260 Vac generator output: Jumper terminal 16–17

Potential transformer burden specifications:

1.6 W per phase (with 230 Vac input)

0.4 W per phase (with 115 Vac input)

  1. 9907-173 Woodward Shielded Wiring

2.1 General Requirements

All shielded cables must use twisted conductors with either foil or braided shielding.

Do not tin (solder) the braided shield.

All signal lines require shielding to prevent interference from stray signals generated by adjacent equipment.

Connect shields to the terminals specified in the plant wiring diagram.

Keep exposed wire beyond the shield as short as possible.

Leave the opposite end of the shields open and insulated from all other conductors.

Do not route shielded signal wires alongside cables carrying large currents.

For additional guidance, refer to Application Note 50532: EMI Control for Electronic Governing Systems.

2.2 Cable Preparation Steps

Strip outer insulation from both ends of the cable to expose the braided or spiral-wrapped shield. Do not cut the shield on the end nearest to the Load Sharing Module; cut off the shield on the end away from the unit.

Use a sharp, pointed tool to carefully spread the strands of the shield.

Pull the inner conductors out of the shield. Twist braided shields to prevent fraying.

Attach lugs to the shield and control wires. Number 6 slotted or round crimp-on terminals are recommended for most installations.

Connect the wires to the appropriate terminals on the module.

2.3 EMI Protection (Severe Environments)

Installations exposed to severe electromagnetic interference (EMI) may require additional precautions, such as:

Shielded wire routed through conduit

Double-shielded wire

Other application-specific EMI mitigation measures

9907-173 PDF
9907-173

♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦

Shipping:
1. Your item will be shipped to all countries via EMS, unless one country cannot be shipped via EMS. We will choose DHL, UPS, or FedEx. Please leave us your phone number.
2. We will ship the product to you on the same day or within 1-2 working days after receiving your payment. The shipping time depends on the country/region where you reside, the customs and habits of your country/region, and especially during peak hours.
3. Assuming (assuming) that the item requires payment of tariffs from your country, the buyer is obligated. We are not responsible for any taxes or customs fees in your country/region.

Return Policy:
1. Please contact us before returning the item.
2. The buyer should inform the seller of all returned items within 7 days after receiving the package. We reserve the right to reject any request to inform the seller for more than 7 days.
3. Returned products must have all original packaging and be in good condition.

Response policy:
If you are satisfied with the purchase, please leave us an active response.
2. If you have any questions about the outcome of the transaction or product, please contact us first and we will do our best to satisfy you!
3. Please do not reply with negative feedback before contacting us!

More models available:

DS200CTBAG1ADD

9905-263

5233-2089

IC8008SI228RD2

8237-1006

5233-2089

8446-1019

EASYGEN-3500-5/P2 8440-2145

9905-017

8200-314