Description
95DSS3-1CEX Fireye InSight Flame Scanner in stock
The sealing coupling, P/N 60-1199-x (see Figure 10, Item D), is used whenever a coupling or a seal is required for scanner piping. The quartz window blocks furnace pressure, hot gases and soot from coming in contact with the scanner and contaminating the lens. 95DSS3-1CEX has a 1″ NPT thread, P/N 60-
1199-2 has a 1″ BSP thread. When the sealing coupling is used, a 1 inch “Y” fitting must be used downstream of it for connection of a purge air supply (plug 3/8”opening). Orifice Kit (Optional) An orifice may be used to restrict the scanner’s field of view aiding discrimination between the target flame and other flames in the combustion chamber. An orifice may also be used to reduce the total amount of radiation reaching the scanner, thereby avoiding the chance of saturation. Orifice kit (P/N53-121) contains nine different orifice sizes, and two retaining clips. The orifice can be installed either within the 60-1664 swivel mount, within the 60-1199 coupling, or within the 95DSS3-1CEX, 60-2919-2 surface mounting flange. Refer to figures 11 and 12.
95DSS3-1CEX Fireye InSight Flame Scanner in stock
95DSS3-1CEX Fireye InSight Flame Scanner in stock
P/N 95DISP-1 is a two-line by sixteen-character alpha-numeric OLED Display with a fivepushbutton keypad. The 95DISP-1 is installed by the user onto the end of the standard scanners enabling the user to view and change the operating parameters and setpoints at the scanner itself. The 95DISP-1-SS is factory installed into the 95DSS3-1CEXSS and 95DSS3-1CEX-2 scanners.Infrared Transmitter, P/N 95WIDISP-2 P/N 95WIDISP-2 is an Infrared Transmitter, installed by the user onto the end of the scanner instead of a display. The 95WIDISP-2 transmitter provides infrared wireless communications to a model 95WIHH-2 hand-held remote communications tool.
95DSS3-1CEX Fireye InSight Flame Scanner in stock
95DSS3-1CEX Fireye InSight Flame Scanner in stock
GROUNDING AND SHIELDING TECHNIQUES FOR USE ON SCANNERS OR SCANNER CABLE LOCATED WITHIN 12″ OF A HIGH
ENERGY OR HIGH VOLTAGE SOURCE.
1. Connect a safety ground to scanner housing (Figure 13 & 14).
2. The scanner and scanner cable MUST be located at least 12″ from the ignition source.
3. Run a ground wire from the ignition transformer chassis to the ignitor assembly.
4. Replace all frayed, cracked, or dirty (oily) ignition wire. Ignition wire must be in good working condition.
5. Electrically isolate the scanner from the burner using the surface mounting flange with integral heat-insulating female thread insert.
6. Cooling/Purge Air must be electrically isolated from the scanner (e.g. isolated short rubber hose)
95DSS3-1CEX Fireye InSight Flame Scanner in stock
♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦
Shipping:
1. Your item will be shipped to all countries via EMS, unless one country cannot be shipped via EMS. We will choose DHL, UPS, or FedEx. Please leave us your phone number.
2. We will ship the product to you on the same day or within 1-2 working days after receiving your payment. The shipping time depends on the country/region where you reside, the customs and habits of your country/region, and especially during peak hours.
3. Assuming (assuming) that the item requires payment of tariffs from your country, the buyer is obligated. We are not responsible for any taxes or customs fees in your country/region.
Return Policy:
1. Please contact us before returning the item.
2. The buyer should inform the seller of all returned items within 7 days after receiving the package. We reserve the right to reject any request to inform the seller for more than 7 days.
3. Returned products must have all original packaging and be in good condition.
Response policy:
If you are satisfied with the purchase, please leave us an active response.
2. If you have any questions about the outcome of the transaction or product, please contact us first and we will do our best to satisfy you!
3. Please do not reply with negative feedback before contacting us!