5233-2089 WOODWARD synchronizer control unit

Brand:WOODWARD

Model:5233-2089

Input Voltage: 18-36VDC

Input Current: 4.3A

Temperature Range: -30<Tamb<70

Manufactured in Fort Collins, CO., U.S.A

MAKE : WOODWARD , USA

Category: Tag:
Whatsapp:+86 13313705507
WeChat:+86 13313705507
E-mail:geabbdcs@gmail.com
Contacts:KEN HE

Description

5233-2089 WOODWARD synchronizer control unit

These controls are available for forward- or reverse-acting applications, and for use with either single or tandem actuators. 5233-2089  for three different actuator current ranges are available, as well as a high-voltage model (90 to 150 Vdc or 88 to 132 Vac, 45 to 440 Hz), and a low-voltage model (20 to 40 Vdc). The high
voltage model is identified as such on the front; the low voltage model is not.In reverse-acting systems, the actuator calls for more fuel when the actuator voltage decreases. Complete loss of voltage to the actuator will drive the actuator to full fuel. This allows a backup mechanical ballhead governor to take control
rather than shut down the prime mover as would a direct-acting system. An optional deceleration ramp is also offered. When this option is present, 5233-2089  to ramp from rated speed to idle speed is approximately 20 seconds. If this option is not present, this happens instantly.

5233-2089 WOODWARD synchronizer control unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5233-2089 WOODWARD synchronizer control unit

The relationship between prime mover speed and sensor output frequency is expressed in the formula:Sensor Frequency in Hz equals the number of teeth on the speed sensing gear times the rated prime mover speed in revolutions per minute divided by 60.
Application engineers from Woodward or any of its authorized distributors or agents are always available to assist you in selection of the correct control for your system, or to answer 5233-2089  concerning control installation, operation, or calibration. See Chapter 6 for contact information. The 2301A control requires a voltage source of 18 to 40 Vdc, 90 to 150 Vdc, or 88 to 132 Vac for operating power (15 W). If a battery is used for operating power, an alternator or other battery charging device is necessary to maintain a stable supply voltage.

5233-2089 WOODWARD synchronizer control unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5233-2089 WOODWARD synchronizer control unit

All shielded cable must be twisted conductor pairs. Do not attempt to tin (solder) the braided shield. All signal lines should be shielded to prevent picking up stray signals from adjacent equipment. Connect the shields to the control terminals as shown in Figure 2-1 and in the plant wiring diagram (Figure 1-2). Wire exposed
beyond the shield should be as short as possible, not exceeding 50 mm (2 inches). The other end of the shields must be left open and insulated from any other conductor. Do not run shielded signal wires with other wires carrying large currents. See Woodward application note 50532, EMI Control for Electronic Governing Systems, for more 5233-2089 .Where shielded cable is required, cut the cable to the desired length and prepare the cable as instructed below and shown in Figure 2-1.
1. Strip outer insulation from BOTH ENDS, exposing the braided or spiral wrapped shield. DO NOT CUT THE SHIELD.
2. Using a sharp, pointed tool, carefully spread the strands of the shield.
3. Pull inner conductor(s) out of the shield. If shield is the braided type, twist to prevent fraying.
4. Remove 6 mm (1/4 inch) of insulation from the inner conductor(s).
5. Connect wiring and shield as shown.In installations with severe electromagnetic interference (EMI), shielded wire run in conduit, double shielded wire, or other precautions may be required. Contact Woodward for more information.

5233-2089 WOODWARD synchronizer control unit

 

♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦

Shipping:
1. Your item will be shipped to all countries via EMS, unless one country cannot be shipped via EMS. We will choose DHL, UPS, or FedEx. Please leave us your phone number.
2. We will ship the product to you on the same day or within 1-2 working days after receiving your payment. The shipping time depends on the country/region where you reside, the customs and habits of your country/region, and especially during peak hours.
3. Assuming (assuming) that the item requires payment of tariffs from your country, the buyer is obligated. We are not responsible for any taxes or customs fees in your country/region.

 

Return Policy:
1. Please contact us before returning the item.
2. The buyer should inform the seller of all returned items within 7 days after receiving the package. We reserve the right to reject any request to inform the seller for more than 7 days.
3. Returned products must have all original packaging and be in good condition.

 

Response policy:
If you are satisfied with the purchase, please leave us an active response.
2. If you have any questions about the outcome of the transaction or product, please contact us first and we will do our best to satisfy you!
3. Please do not reply with negative feedback before contacting us!

Related models:

UFC721BE101 3BHE021889R0101
UFC760BE01 3BHB007030R0001
UFC760BE143 3BHE004573R0143
UFC760BE41 3BHE004573R0041
UFC760BE42 3BHE004573R0042
UFC762AE101 3BHE006412R0101
UFD203A101 3BHE019361R0101
UMB015BE02 HIEE400995R0002
UNITROL 1005-0011 ECO 3BHE043576R0011
UNITROL 1010 3BHE035301R1002
UNITROL 1020 3BHE030579R0003
UNITROL 1020 3BHE030579R0003 UNS0119A-Z,V1 3BHE030579R0001
UNITROL1000 B-Z V104 3BHE014557R6104
UNITROL1000 Z.V3 3BHE014557R0003
UNS0880A-P,V1 3BHB005922R0001
UNS0883A-P,V1 3BHB006208R0001