Description
Pre-Installation Checks
-
Environmental Limits
- Temperature: -10°C to +60°C (derate flow 0.8%/°C >40°C)
- Air Quality: ISO 8573-1 Class 3.4.2 (3µm filtration required)
- Pressure: 0.15-10 bar (lubricated operation recommended)
-
Component Verification
- Confirm label markings: ▷ P (Pressure), A/B (Actuator), R/S (Exhaust)
- Check coil voltage: Blue/Brown wires = 24V DC (±10%)
Mounting Procedure
Step 1: Mechanical Installation
1. Mount on ISO 5599-1 compliant manifold (e.g. Festo CPE18-M3H)
2. Fastening torque:
• Manifold screws: 1.5 Nm ±0.3 Nm
• Port connectors: 15 Nm ±2 Nm
3. Alignment tolerance: ≤0.2mm lateral shift
Step 2: Pneumatic Connections
| Port | Function | Tubing Size | Sealing Method |
|---|---|---|---|
| P | Supply pressure | Ø12mm | PTFE tape (3 wraps max) |
| A/B | Actuator lines | Ø8mm | Push-in fitting (2.5mm dep) |
| R/S | Exhaust | Not connected | Muffler (SFAM-12) |
Electrical Wiring
[Terminal Assignments]
Pin 1: 24V DC+ (Brown)
Pin 2: 0V DC- (Blue)
Pin 3: Analog command (0-10V)
Pin 4: Feedback signal (4-20mA)
[Requirements]
• Use shielded cable (CY type)
• Ground shield at controller end only
• Max lead length: 15m (25m with 0.75mm² wire)
• Separate from power cables by ≥200mm
Commissioning Sequence
-
Pneumatic Test
- Apply 6 bar pressure → check for leaks with soap solution
- Cycle valve 5x at 1Hz before calibration
-
Electrical Validation
multimeterCopy CodeInput impedance: Pin1-Pin2 = 45Ω ±5%
Feedback output: Pin4-Pin2 = 12.5mA @ mid-stroke
-
Calibration (Via Festo Motion Manager)
iniCopy Code[Valve_Cal]
Stroke_Time=120ms ; Adjust PWM frequency
Null_Offset=0.12V ; Compensate spool overlap
Deadband=2% ; Hysteresis compensation
Critical Warnings
PROHIBITED ACTIONS
- Never energize before pneumatic supply → coil burnout risk
- Don’t exceed 100% duty cycle >30 seconds
- Avoid mounting position where exhaust ports face downward
SAFETY INTERLOCKS
- Install mechanical lock (Part No. ELGA-10) during maintenance
- Implement emergency decay circuit:
textCopy Code
--[ ]--|VM52_FB<10%|--(K1)--
K1 contacts bypass analog command
Compliance Specifications
Standard Article Requirement
ISO 13849-1 PLd Category 3 Dual-channel monitoring
ATEX Directive 2014/34/EU II 3G Ex h IIC T4 Gc
RoHS 3 Annex III Cadmium <0.01%
Post-Installation Verification
-
Dynamic Response Test
- 10-90% step response: ≤85ms (0.5Hz sine wave)
- Hysteresis: ≤1.5% FS
-
Diagnostic Indicators
LED State Fault Condition Green flashing (1Hz) Coil temperature >85°C Red solid Spool jamming detected Off with power Open circuit (check fuse F2)
33VM52-000-29 PACIFIC SCIENTIFIC PDF
33VM52-000-29 PACIFIC SCIENTIFIC
♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦
Shipping:
1. Your item will be shipped to all countries via EMS, unless one country cannot be shipped via EMS. We will choose DHL, UPS, or FedEx. Please leave us your phone number.
2. We will ship the product to you on the same day or within 1-2 working days after receiving your payment. The shipping time depends on the country/region where you reside, the customs and habits of your country/region, and especially during peak hours.
3. Assuming (assuming) that the item requires payment of tariffs from your country, the buyer is obligated. We are not responsible for any taxes or customs fees in your country/region.
Return Policy:
1. Please contact us before returning the item.
2. The buyer should inform the seller of all returned items within 7 days after receiving the package. We reserve the right to reject any request to inform the seller for more than 7 days.
3. Returned products must have all original packaging and be in good condition.
Response policy:
If you are satisfied with the purchase, please leave us an active response.
2. If you have any questions about the outcome of the transaction or product, please contact us first and we will do our best to satisfy you!
3. Please do not reply with negative feedback before contacting us!
More models available: