ABB 0-60063-1 Drive Module – Parameter Configuration Protocol
1. Pre-Configuration Requirements
Critical Precautions:
- Disable drive power & verify DC bus voltage <5V (NFPA 70E Category II PPE required)
- Confirm hardware label: “0-60063-1” and firmware version (OLED display code
FW:xxx) - Connect programming device:
- HMI: CDP-312C panel
- Software: DriveComposer PC tool (v2.22+) via USB/FCP
2. Parameter Access Hierarchy
graph LR
A[Main Menu] --> B[10: MOTOR DATA]
A --> C[20: SPEED CONTROL]
A --> D[30: TORQUE LIMITS]
A --> E[99: ADVANCED PARAMETERS]
E --> F[99.05: SIL2 CONFIG]
► Use navigation keys: ▲/▼ for selection, ENTER for edit mode
3. Essential Parameter Groups
Group 10: Motor Data
| Parameter | Path | Default | Recommended Value |
|---|---|---|---|
| Motor Nominal Power | 10.01 | 0.75 kW | <Your Motor Rating> |
| Motor Nominal Speed | 10.04 | 1430 rpm | Per motor plate data |
| Motor Nominal Current | 10.05 | 1.8 A | +10% derating |
| Motor Control Mode | 10.22 | SCALAR | DTFC (Direct Torque) |
Group 20: Speed Reference
| Parameter | Path | Critical Settings |
|---|---|---|
| Speed Source | 20.01 | 3: FCP (Fieldbus) |
| Max Speed | 20.02 | ≤95% of motor max (IEC 60034-1) |
| Acceleration Time 1 | 20.04 | 5.0 s → Calibrate per load inertia |
Group 30: Protection
30.13 Motor Therm Time: 20 min → ‌**Set per motor class (B/F/H)**‌
30.22 Earth Fault Action: 0 → ‌**2: Coast & Trip**‌ (IEC 61800-5-1)
4. Safety Configuration (SIL2)
- Enable safety input:
- Parameter 99.05.01:
SAFE TORQUE OFF= ENABLED
- Parameter 99.05.01:
- Verify redundant channel wiring:
- STO1+: Terminal X5:21
- STO1-: Terminal X5:22
- STO2+: Terminal X5:23
- STO2-: Terminal X5:24
- Validate function:
- Apply 24VDC → Drive enables
- Disconnect either channel → Immediate torque cutoff
5. Commissioning Sequence
- Auto-Tuning (Stationary):
- Set
98.02= 1: STANDARD + Start - Wait for “TUNE OK” on display (≈2 min)
- Set
- Direction Verification:
- Jog at 5% speed (
16.01) → Confirm motor rotation
- Jog at 5% speed (
- Torque Reference Setup:
textCopy Code
22.01 = 150% (Standard)
22.02 = 180% (Boost)
22.03 = 0.1 s (Boost time)
6. Post-Configuration Checks
| Test | Procedure | Pass Criteria |
|---|---|---|
| Parameter Lock | Set 16.04 = LOCKED |
“PAR LOCKED” displayed |
| Fault History Clear | Menu → FAULT LOG → Reset | No active faults (LED green) |
| Backup Configuration | DriveComposer → Save .dcf file | SHA-256 checksum verified |
7. Critical Notes
- Never change parameters under load – causes flux estimation errors
- Derating Requirements:
- Ambient >40°C: Reduce current 3%/°C (Parameter 30.12)
- Validation Standards:
- Functional Safety: IEC 61800-5-2 SIL2 Cat.3
- EMC: EN 61800-3 Class C3
0-60063-1 ABB pdf
♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦♦…♦
Shipping:
1. Your item will be shipped to all countries via EMS, unless one country cannot be shipped via EMS. We will choose DHL, UPS, or FedEx. Please leave us your phone number.
2. We will ship the product to you on the same day or within 1-2 working days after receiving your payment. The shipping time depends on the country/region where you reside, the customs and habits of your country/region, and especially during peak hours.
3. Assuming (assuming) that the item requires payment of tariffs from your country, the buyer is obligated. We are not responsible for any taxes or customs fees in your country/region.
Return Policy:
1. Please contact us before returning the item.
2. The buyer should inform the seller of all returned items within 7 days after receiving the package. We reserve the right to reject any request to inform the seller for more than 7 days.
3. Returned products must have all original packaging and be in good condition.
Response policy:
If you are satisfied with the purchase, please leave us an active response.
2. If you have any questions about the outcome of the transaction or product, please contact us first and we will do our best to satisfy you!
3. Please do not reply with negative feedback before contacting us!
More models available: